>pDRIVE< MX top
Frequency inverter in a cubicle from 160
up to 1500 kW (3AC 690V) with 6- or 12-pulse commutation.
|

|
Complex high-tech solutions designed for
690 V mains. The electronic design of >pDRIVE<
MX top is ideally suitable for capacities of up to
1.5 MW. The control parameters are optimised by setting
the motor rating plate data and auto-tuning during standstill.
Special functions tuned to the various applications increase
the customer benefits as well as the operational safety:
- The automatic motor load limitation
protects the motor and prevents troublesome fault disconnections
in pump and fan drives.
- A variable load balancing control prevents
imbalances in parallel motors with combined loads.
- Where required, the entire drive is
connected by means of the automatic line contactor control
to the mains via the control terminal strip or the field
bus.
- Options such as 12-pulse rectification,
insulation monitoring, PT100 motor monitoring and many
more are possible with these devices
Please click the button to get a free
non-binding offer!

|
| General
technical data |
|
Mains voltage
|
3- phase 690 V -10%
+10%; 50-60 Hz
|
| Maximum
current |
150% for high overload / 120 % for high continuous
load (min. 60s/10min) |
|
Control process
|
AVC (Auto-Vector-Control)
with and without shaft encoder
|
| Design |
Cubicle device with protection degree IP23 |
| Intelligent
control terminal |
4
(max. 12) digital inputs (24 V DC, potential free)
2 (max. 4) analog inputs (0...10 V, 4...20 mA), 1
(max. 3) analog outputs (0(4)...20mA)
1 (max. 5) relay (change-over contact: 24 V DC/230
V AC)
Input for Motor-thermistor |
| Integrated
user interface |
Clear
text LCD display, 3 signal lamps, 8 function keys,
serial interfaces RS 232 built in according to the
norm (connection for PC by means of the Software
MatriX or gateways) |
| Options |
- terminal strip extension IO1
- Profibus DP option card PBO1
- Option SFB (speed feedback)
- gateways for interbus GW-IBO1,
CANopen GW-CBO1 and DeviceNet GW-DBO1
- installable RFI filter (for TT/TN
and IT)
- output motor filter AMF
|
|
Specific functions
|
line contactor control, emergency operation,
motor heating, catch on the fly function, automatic
motor load limitation, motor brakes without braking
unit |
|
Documentation
|
|
|
>pDRIVE<
MX
|
Output
current
|
Rated
motor power
|
| MX
top 160/200 |
190
/ 230 A
|
160 / 200 kW
|
| MX
top 200/250 |
230
/ 275 A
|
200 / 250 kW
|
| MX
top 250/315 |
285
/ 340 A
|
250 / 315 kW
|
| MX
top 315/400 |
350
/ 420 A
|
315 / 400 kW
|
| MX
top 400/500 |
435
/ 520 A
|
400 / 500 kW
|
| MX
top 500/630 |
550
/ 660 A
|
500 / 630 kW
|
| MX
top 630/800 |
700
/ 840 A
|
630 / 800 kW
|
| MX
top 800/1000 |
875
/ 1050 A
|
800 / 1000 kW
|
| MX
top 1000/1200 |
1050
/ 1260 A
|
1000 / 1200 kW
|
| MX
top 1200/1500 |
1320
/ 1580 A
|
1200 / 1500 kW
|
|
|
| |
©
2007 by Schneider Electric Power Drives GmbH
|
|