>pDRIVE< MX top

Frequency inverter in a cubicle from 160 up to 1500 kW (3AC 690V) with 6- or 12-pulse commutation.

>pDRIVE< MX top

 

Complex high-tech solutions designed for 690 V mains. The electronic design of >pDRIVE< MX top is ideally suitable for capacities of up to 1.5 MW. The control parameters are optimised by setting the motor rating plate data and auto-tuning during standstill.
Special functions tuned to the various applications increase the customer benefits as well as the operational safety:

  • The automatic motor load limitation protects the motor and prevents troublesome fault disconnections in pump and fan drives.
  • A variable load balancing control prevents imbalances in parallel motors with combined loads.
  • Where required, the entire drive is connected by means of the automatic line contactor control to the mains via the control terminal strip or the field bus.
  • Options such as 12-pulse rectification, insulation monitoring, PT100 motor monitoring and many more are possible with these devices

Please click the button to get a free non-binding offer!

Click here for a free non-binding offer!

 

 

General technical data
Mains voltage
3- phase 690 V -10% +10%; 50-60 Hz
Maximum current 150% for high overload / 120 % for high continuous load (min. 60s/10min)
Control process
AVC (Auto-Vector-Control) with and without shaft encoder
Design Cubicle device with protection degree IP23
Intelligent control terminal 4 (max. 12) digital inputs (24 V DC, potential free)
2 (max. 4) analog inputs (0...10 V, 4...20 mA), 1 (max. 3) analog outputs (0(4)...20mA)
1 (max. 5) relay (change-over contact: 24 V DC/230 V AC)
Input for Motor-thermistor
Integrated user interface Clear text LCD display, 3 signal lamps, 8 function keys, serial interfaces RS 232 built in according to the norm (connection for PC by means of the Software MatriX or gateways)
Options

- terminal strip extension IO1
- Profibus DP option card PBO1
-
Option SFB (speed feedback)
-
gateways for interbus GW-IBO1, CANopen GW-CBO1 and DeviceNet GW-DBO1
- installable RFI filter (for TT/TN and IT)
- output motor filter AMF

Specific functions
line contactor control, emergency operation, motor heating, catch on the fly function, automatic motor load limitation, motor brakes without braking unit
Documentation

 

>pDRIVE< MX
Output current
Rated motor power
MX top 160/200
190 / 230 A
160 / 200 kW
MX top 200/250
230 / 275 A
200 / 250 kW
MX top 250/315
285 / 340 A
250 / 315 kW
MX top 315/400
350 / 420 A
315 / 400 kW
MX top 400/500
435 / 520 A
400 / 500 kW
MX top 500/630
550 / 660 A
500 / 630 kW
MX top 630/800
700 / 840 A
630 / 800 kW
MX top 800/1000
875 / 1050 A
800 / 1000 kW
MX top 1000/1200
1050 / 1260 A
1000 / 1200 kW
MX top 1200/1500
1320 / 1580 A
1200 / 1500 kW
 

© 2007 by Schneider Electric Power Drives GmbH